Total Hip Arthroplasty Biomechanics
A real total hip construct in 3D: change the neck design, head size and stem, then watch offset, limb length, arc to impingement, jump distance, joint load and stress shielding change, measured live on the model.
What you can do
- Seven lessons from Campbell's hip arthroplasty chapter: component geometry, offset, head size, skirted heads, jump distance, joint forces and stress transfer.
- Read offset, vertical height, neck length, stem length and distal stem diameter, measured live on a real total hip construct.
- Switch between a standard, a more valgus and a medialized neck and see what happens to offset and limb length.
- Change the head from 22 to 40 mm and follow polyethylene thickness, head-neck ratio and jump distance.
- Abduct the hip until the neck meets the liner rim and compare circular and trapezoidal necks and skirted heads.
- Show the abductor and body-weight lever arms on a force diagram and medialize the cup to change the joint load.
- Ten one-click board cases, plus a radiograph view, a ruler and section cuts.
Key concepts
Offset is the distance from the center of the femoral head to the axis of the distal stem; too little offset shortens the abductor lever arm and raises joint reaction force, limp and impingement.
A larger head raises the head-neck ratio and the arc of motion before impingement, and its jump distance is about half the head diameter; polyethylene thinner than 5 mm is at risk of early failure.
The abductors work on a lever: with a body-weight to abductor lever arm ratio of about 2.5 to 1, the load on the femoral head in stance is about three times body weight.
Further reading
- Campbell's Operative Orthopaedics, 2026 edition: ch 4, Arthroplasty of the Hip (biomechanics and component design).
- Every quoted number in the simulator is traced to a Campbell 2026 page; the lessons also show the matching figure and page numbers of the 14th edition.
- Measured values (offset, vertical height, neck length, polyethylene thickness, arc to impingement) are taken live on the 3D construct in the simulator.

Designed for Orthoverse by Dr. M. M. Bakhshaei. Built to make orthopedic concepts visible, measurable and easy to explore.
Have an idea for the next simulator?
Tell us which concept you would like to explore. Message our bot and we will read every idea.
For medical education only. Orthoverse simulators are teaching models for health professionals and students. They are simplified on purpose, are not medical devices and are not a substitute for clinical judgement, patient-specific imaging or the original literature.
© 2026 Orthoverse. All rights reserved. The simulators, their code, drawings and models are original work. Free to use for learning on orthoverse.org; copying, embedding, scraping or redistribution is not permitted. Textbook references are cited for further reading only.